Waste Water Treatment Plant
Waste Water Treatment Plant comprises of various treatment scheme to desired water as per appropriate discharge norms or appropriate further application (e.g. Pollution Control Board Norms, CETP intake norms, for Recycling purpose, washing water, gardening water, etc.) from waste water with different impurity level (e.g. low strength industrial waste water, High strength industrial waste water, sewage water, reject of water treatment plant etc.).
We are offering following option to meet Treated Water Quality according to discharge norms or appropriate recycle water application:
Option-1:
Waste Water Treatment scheme to achieve effluent with discharge norms from different sources of waste water.
Source of Waste Water
- High COD/High TDS Effluent
- Low COD/Low TDS Effluent
- Sewage Water
- Reject of Water Treatment Plant
Waste Water Treatment Plant
- Effluent Treatment Plant
- Sewage Water Treatment Plant
- Chemical Treatment
Treated Water Purpose Application
- To Maintain PCB
- CETP Guidelines
- Inlet Norms of ERS
- Gardening & Washing
Option-2:
Waste Water Treatment scheme to achieve recycle water from different sources of waste water.
Source of Waste Water
- High COD/High TDS Effluent
- Low COD/Low TDS Effluent
- Sewage Water
- Reject of Water Treatment Plant
Waste Water Treatment Plant
-
Effluent Treatment Plant (ETP)
- Effluent Treatment Plant
- Sewage Water Treatment Plant
- Chemical Treatment
-
ETP Recycling System (ERS)
- ERS (ETP Recycling System)
- ZLD (Zero Liquid Discharge System)
Treated Water Purpose Application
- Boiler Feed Water
- Utility Water
- Cooling Tower Move-Up
- Process Water
Targeted Impurities
- pH
- TSS
- Turbidity
- O&G
- Color
- COD
- BOD
- TDS
- Alkalinity
- Total Hardness
- Calcium
- Magnesium
- Bicarbonate
- Carbonate
- Chloride
- Sulphate
- Ammonical Nitrogen
- Nitrate
- Nitrate
- Free Ammonia
- Total Nitrogen
- PO4-P
- Total Phosphate
- Colloidal Silica
- Reactive Silica
- Floride
- Dissolved Oxygen (DO)
- TOC
- Boron
- Heavy Metals
- Free CO2
- Iron
- Manganese
- Low Boil Solvent (Name & Quantity)
- Low Boil Solvent (Name & Quantity)
General Treatment Scheme
Waste Water Treatment Plant (WWTP)
Prelimnary
Screening
Grit Removal
Flow Equalization
Primary
Chemical Coagulation
Flocculation
Primary Clarification / Settling / Sedimentation
Biological Treatment / Secondary Treatment
Anaerobic Treatment
Anoxic Treatment
Secondary Clarifcation
Advanced Oxidation Processes (AOP)
- Fenton Reagent Process
Tertiary Treatment
Granular Media Filtration
Activated Carbon Filtration
Waste Water Treatment Plant (WWTP)
Prelimnary
Screening
Grit Removal
Flow Equalization
Primary
Chemical Coagulation
Flocculation
Primary Clarification / Settling / Sedimentation
Biological Treatment / Secondary Treatment
Secondary Clarifcation
Advanced Oxidation Processes (AOP)
- Fenton Reagent Process
Tertiary Treatment
Granular Media Filtration
Activated Carbon Filtration
Industries We Serve
We are offering following option to meet Treated Water Quality according to discharge norms or appropriate recycle water application:
Option-1: Waste Water Treatment scheme to achieve effluent with discharge norms from different sources of waste water.
Source of Waste Water
- High COD/High TDS Effluent
- Low COD/Low TDS Effluent
- Sewage Water
- Reject of Water Treatment Plant
Waste Water Treatment Plant
- Effluent Treatment Plant
- Sewage Water Treatment Plant
- Chemical Treatment
Treated Water Purpose Application
- To Maintain PCB
- CETP Guidelines
- Inlet Norms of ERS
- Gardening & Washing
Option-2: Waste Water Treatment scheme to achieve recycle water from different sources of waste water.
Source of Waste Water
- High COD/High TDS Effluent
- Low COD/Low TDS Effluent
- Sewage Water
- Reject of Water Treatment Plant
Waste Water Treatment Plant
-
Effluent Treatment Plant (ETP)
- Effluent Treatment Plant
- Sewage Water Treatment Plant
- Chemical Treatment
-
ETP Recycling System (ERS)
- ERS (ETP Recycling System)
- ZLD (Zero Liquid Discharge System)
Treated Water Purpose Application
- Boiler Feed Water
- Utility Water
- Cooling Tower Move-Up
- Process Water
Targeted Impurities
- pH
- TSS
- Turbidity
- O&G
- Color
- COD
- BOD
- TDS
- Alkalinity
- Total Hardness
- Calcium
- Magnesium
- Bicarbonate
- Carbonate
- Chloride
- Sulphate
- Ammonical Nitrogen
- Nitrate
- Nitrate
- Free Ammonia
- Total Nitrogen
- PO4-P
- Total Phosphate
- Colloidal Silica
- Reactive Silica
- Floride
- Dissolved Oxygen (DO)
- TOC
- Boron
- Heavy Metals
- Free CO2
- Iron
- Manganese
- Low Boil Solvent (Name & Quantity)
- Low Boil Solvent (Name & Quantity)
General Treatment Scheme
Waste Water Treatment Plant (WWTP)
Prelimnary
Screening
Grit Removal
Flow Equalization
Primary
Chemical Coagulation
Flocculation
Primary Clarification / Settling / Sedimentation
Biological Treatment / Secondary Treatment
Anaerobic Treatment
Anoxic Treatment
Secondary Clarifcation
Advanced Oxidation Processes (AOP)
- Fenton Reagent Process
Tertiary Treatment
Granular Media Filtration
Activated Carbon Filtration
Waste Water Treatment Plant (WWTP)
Prelimnary
Screening
Grit Removal
Flow Equalization
Primary
Chemical Coagulation
Flocculation
Primary Clarification / Settling / Sedimentation
Biological Treatment / Secondary Treatment
Secondary Clarifcation
Advanced Oxidation Processes (AOP)
- Fenton Reagent Process
Tertiary Treatment
Granular Media Filtration
Activated Carbon Filtration